| 1 | Intelligent Three-Phase Switched PDU | High-density enterprise racks and colocation facilities | 380–415 V AC, 3-phase, 32–63 A, IEC 60309 input | Approximately 17–43 kW, depending on voltage and amperage | 36–42 × IEC C13; 6–12 × IEC C19 | Outlet-level metering, remote outlet switching, current, voltage, power, energy, temperature and network alarms | Vertical 0U | Maximum rack density | Confirm phase balancing, breaker coordination, network protocol support and local electrical-code approval |
| 2 | Metered Three-Phase PDU | Facilities requiring accurate load visibility without remote outlet switching | 380–415 V AC, 3-phase, 16–32 A | Approximately 8–22 kW | 24–36 × IEC C13; 4–8 × IEC C19 | Aggregate and phase-level current, voltage, power and energy metering | Vertical 0U or 1U horizontal | Strong monitoring-to-cost ratio | Check meter accuracy, display visibility, data logging and compatibility with the DCIM platform |
| 3 | Switched Single-Phase PDU | Remote rebooting and power sequencing for standard server cabinets | 208–240 V AC, single-phase, 16–32 A | Approximately 3.3–7.4 kW | 24–36 × IEC C13; 4–8 × IEC C19 | Remote outlet switching, outlet grouping, scheduling, sequencing and circuit-level metering | Vertical 0U or 1U horizontal | Excellent remote management | Verify switching limits, outlet-level permissions, fail-safe behavior and dual-network access options |
| 4 | Outlet-Metered High-Density PDU | AI, GPU and high-performance computing racks | 208–240 V AC, single-phase or 3-phase, 32–63 A | Approximately 7.4–43 kW | Up to 42 × IEC C13/C19, with a high proportion of C19 outlets | Per-outlet current, power and energy measurement; branch and phase monitoring | Vertical 0U | Granular capacity planning | Check connector temperature ratings, outlet spacing, maximum continuous load and compatibility with high-wattage power supplies |
| 5 | Basic High-Current PDU | Stable server racks where centralized monitoring is already available | 208–240 V AC, single-phase, 32–63 A | Approximately 7.4–14.4 kW | 24–36 × IEC C13; 6–12 × IEC C19 | No network management; local circuit protection and optional visual load indication | Vertical 0U | Low acquisition cost | Confirm upstream protection, plug type, cable length, derating requirements and available rack mounting space |
| 6 | 1U Horizontal Metered PDU | Small server rooms, edge cabinets and shallow network racks | 100–240 V AC, single-phase, commonly 10–16 A | Approximately 2.4–3.8 kW at 240 V | 8–12 × IEC C13 or regional socket outlets | Local current and voltage display; selected models provide network monitoring | 1U horizontal | Space-efficient installation | Measure rack depth, confirm front or rear cable routing and check whether outlets interfere with equipment power supplies |
| 7 | Dual-Input Transfer PDU | Single-corded equipment connected to two independent power sources | Two independent 208–240 V AC inputs, typically 16–32 A | Approximately 3.3–7.4 kW, subject to source and transfer limits | 16–24 × IEC C13; 4–8 × IEC C19 | Input-source status, load monitoring and automatic transfer between sources | Vertical 0U or 1U horizontal | Improved power-path resilience | Check transfer time, source synchronization, bypass operation, input protection and compatibility with UPS systems |
| 8 | Environmental-Monitoring PDU | Unmanned edge sites, telecom rooms and distributed data centres | 100–240 V AC, single-phase, 10–32 A | Approximately 2.4–7.4 kW at 240 V | 8–24 × IEC C13 or regional socket outlets | Temperature, humidity, door and leak-sensor inputs; optional circuit-level metering | Vertical 0U or 1U horizontal | Remote site awareness | Confirm sensor compatibility, alert delivery methods, cellular or Ethernet connectivity and local data retention |
| 9 | IEC Socket PDU for Global Deployment | Multinational rollouts requiring standardized international connections | 230 V AC, single-phase, commonly 16–32 A | Approximately 3.7–7.4 kW | IEC C13/C19 outlets with IEC 60320 or IEC 60309 input options | Basic, metered or network-managed versions available | Vertical 0U or 1U horizontal | Simplified global standardization | Validate country-specific plugs, voltage systems, certifications, cable markings and replacement-part availability |
| 10 | Locking-Outlet PDU | Racks requiring improved retention in vibration-prone or service-intensive environments | 100–240 V AC, single-phase, 10–32 A | Approximately 2.4–7.4 kW at 240 V | Locking IEC C13/C19 or compatible retained outlets | Basic, circuit-metered or remotely monitored configurations | Vertical 0U or 1U horizontal | Secure cable connections | Check plug-and-outlet compatibility, connector availability, service procedures and whether locking features fit installed equipment cords |